meta data for this page
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
sector:ippu:mineral_industry:construction_demolition:start [2024/01/16 09:00] – [Table] kotzulla | sector:ippu:mineral_industry:construction_demolition:start [2024/11/06 13:54] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 3: | Line 3: | ||
===== Short description ===== | ===== Short description ===== | ||
- | ^ Category Code ^ Method | + | ^ Category Code ^ Method |
- | | 2.A.5.b | + | | 2.A.5.b |
- | | {{page> | + | | {{page> |
+ | |||
+ | ---- | ||
| NO< | | NO< | ||
- | | NA | + | | NA |
| {{page> | | {{page> | ||
Line 17: | Line 19: | ||
===== Methodology ===== | ===== Methodology ===== | ||
- | Since the last update of the UNECE Guidebook, a Tier 1 method is applied to estimate particulate matter emissions. | + | Since the last update of the UNECE Guidebook, a Tier 1 method is applied to estimate particulate matter emissions. The T1 GB method is used by us with various adaptations to national conditions, so this is already higher tier, perhaps as T1/T2. |
- | The approach for uncontrolled fugitive emissions for this source category was adapted for national circumstances within a research Project (Umweltbundesamt, | + | The approach for uncontrolled fugitive emissions for this source category was adapted for national circumstances within a research Project (Umweltbundesamt, |
==== Activity data ==== | ==== Activity data ==== | ||
Line 27: | Line 29: | ||
==== Emission factors ==== | ==== Emission factors ==== | ||
- | The emission factors used are results of Adaptation of UNECE-Defaults (EEA, 2016) [(EEA2016> | + | The emission factors used are results of Adaptation of UNECE-Defaults (EEA, 2016) [(EEA2023> |
- | __Table 1: Overview of apllied emission factors, in [kg / m< | + | __Table 1: Overview of apllied emission factors, in [kg / m< |
^ Kind of building | ^ Kind of building | ||
| single and two-family houses | | single and two-family houses | ||
Line 47: | Line 49: | ||
| EM = EF * B * f * m || | | EM = EF * B * f * m || | ||
- | The EF is adapted with Moisture Level Correction factor and Silt Content Correction factor in all cases, both 0.20 and 2.22. The assumption about the duration of the construction activity uses the Default values (EEA, 2016)[(EEA2016)]: | + | The EF is adapted with Moisture Level Correction factor and Silt Content Correction factor in all cases, both 0.20 and 2.22. The assumption about the duration of the construction activity uses the Default values (EEA, 2023)[(EEA2023)]: |
^ Type of building | ^ Type of building | ||
| Construction of houses (single and two family) | | Construction of houses (single and two family) | ||
Line 60: | Line 62: | ||
[{{: | [{{: | ||
+ | |||
+ | Notes to PCB emissions of old buildings are given in chapter [[sector: | ||
===== Recalculations ===== | ===== Recalculations ===== |