meta data for this page
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| general:assessment_completeness:start [2025/04/22 14:17] – [NFR categories reported as 'not estimated' ('NE')] reichel | general:assessment_completeness:start [2026/03/30 16:00] (current) – [Table] kotzulla | ||
|---|---|---|---|
| Line 39: | Line 39: | ||
| The use of notation keys in the German inventory is carefully checked each year. All notation keys are used as defined in the guidance documents. | The use of notation keys in the German inventory is carefully checked each year. All notation keys are used as defined in the guidance documents. | ||
| - | The following tables from the CLRTAP Stage 1 Reviews | + | The following tables from the CLRTAP Stage 1 Reviews |
| Though NEs are great in number, the actual emission behind each of the notation keys is estimated to be very small. In some cases, it is actually used instead of NA to make absolutely sure to be on the conservative side of the estimate. | Though NEs are great in number, the actual emission behind each of the notation keys is estimated to be very small. In some cases, it is actually used instead of NA to make absolutely sure to be on the conservative side of the estimate. | ||
| Line 49: | Line 49: | ||
| * The entire //NFR 2.J - Production of POPs// is reported as not occuring in Germany now and all NE have been replacd by NO notations. | * The entire //NFR 2.J - Production of POPs// is reported as not occuring in Germany now and all NE have been replacd by NO notations. | ||
| - | [{{: | ||
| - | [{{ : | ||
| - | As for categories, NE notations are used mainly in **Industrial Processes** and **Waste** (please refer to [[https:// | + | | [{{ : |
| + | |||
| + | \\ | ||
| + | |||
| + | As for categories, NE notations are used mainly in **Industrial Processes** and **Waste** (please refer to [[https:// | ||
| Each use is individually justified in the corresponding source category sections of this report as well as in the table below. | Each use is individually justified in the corresponding source category sections of this report as well as in the table below. | ||
| Line 69: | Line 71: | ||
| | 1.A.3.b i-iv | HCB | no country-specific EF at hand; no default provided in [[https:// | | 1.A.3.b i-iv | HCB | no country-specific EF at hand; no default provided in [[https:// | ||
| | 1.A.3.b vi | B[k]F | no country-specific EFs at hand; no defaults for BC provided in [[https:// | | 1.A.3.b vi | B[k]F | no country-specific EFs at hand; no defaults for BC provided in [[https:// | ||
| - | | 1.A.3.b vii | Hg, Se as of 2000: BC | no country-specific EFs at hand; no defaults for BC provided in [[https:// | + | | 1.A.3.b vii | Hg, Se | no country-specific EFs at hand; no defaults for BC provided in [[https:// |
| | 1.A.3.e i | as of 2000: BC | no EF provided in [[https:// | | 1.A.3.e i | as of 2000: BC | no EF provided in [[https:// | ||
| | 1.A.4.a i | Se | several EFs provided in [[https:// | | 1.A.4.a i | Se | several EFs provided in [[https:// | ||
| Line 82: | Line 84: | ||
| | 2.B.3 | PM< | | 2.B.3 | PM< | ||
| | 2.B.7 | as of 1995: PM< | | 2.B.7 | as of 1995: PM< | ||
| - | | 2.C.1 | As, Cu, Se, Zn, B[a]P, B[b]F, B[k]F, I[1, | + | | 2.C.1 | As, Cu, Se, Zn, B[a]P, B[b]F, B[k]F, I[1, |
| - | | 2.C.2 | NO< | + | | 2.C.2 | NO< |
| - | | 2.C.3 | NMVOC, Cr, Se \\ BC, B[b]F, B[k]F, I[1, | + | | 2.C.3 | NMVOC, Cr, Se \\ \\ BC | [[https:// |
| | 2.C.4 | NMVOC, TSP, PM< | | 2.C.4 | NMVOC, TSP, PM< | ||
| - | | 2.C.5 | BC (as of 2000), Se | [[https:// | + | | 2.C.5 | BC (as of 2000), Se | [[https:// |
| - | | 2.C.6 | BC (as of 2000), Se | [[https:// | + | | 2.C.6 | BC (as of 2000), Se | [[https:// |
| - | | 2.C.7.a | + | | 2.C.7.a |
| - | | 2.C.7.c | + | | 2.C.7.c |
| | 2.D.3.b | | 2.D.3.b | ||
| - | | 2.D.3.c | + | | 2.D.3.c |
| | 2.H.1 | NH3, PCBs, as of 2000: BC | use of default EF will be checked for BC, use of ' | | 2.H.1 | NH3, PCBs, as of 2000: BC | use of default EF will be checked for BC, use of ' | ||
| | 2.H.2 | as of 2000: BC | use of default EF will be checked for following submissions | | 2.H.2 | as of 2000: BC | use of default EF will be checked for following submissions | ||
| Line 122: | Line 124: | ||
| | 2.A.6 | CO | 1.A.2.f | | 2.A.6 | CO | 1.A.2.f | ||
| | 2.B.10.b | | 2.B.10.b | ||
| + | | 2.C.4 | NO< | ||
| | 2.C.7.d | | 2.C.7.d | ||
| | 2.I | CO | 1.A.2 | | 2.I | CO | 1.A.2 | ||