sector:energy:fuel_combustion:small_combustion:stationary_small_combustion:commercial_institutional [2023/04/12 18:05] – [Particulate Matter - PM2.5 & PM10 & TSP] kludtsector:energy:fuel_combustion:small_combustion:stationary_small_combustion:commercial_institutional [2023/04/17 13:40] – [Table] kludt
Line 19: Line 19:
 ==== Activity data ==== ==== Activity data ====
  
-For further information on activity data please refer to the [[sector:energy:fuel_combustion:small_combustion:stationary_small_combustion |superordinte chapter]] on small stationary combustion.+For further information on activity data please refer to the [[sector:energy:fuel_combustion:small_combustion:stationary_small_combustion |superordinate chapter]] on small stationary combustion.
  
 ==== Emission factors ==== ==== Emission factors ====
  
-For further information on the emission factors applied please refer to the [[sector:energy:fuel_combustion:small_combustion:stationary_small_combustion |superordinte chapter]] on small stationary combustion.+For further information on the emission factors applied please refer to the [[sector:energy:fuel_combustion:small_combustion:stationary_small_combustion |superordinate chapter]] on small stationary combustion.
  
 __Table 1: Emission factors for commercial and institutional combustion installations__ __Table 1: Emission factors for commercial and institutional combustion installations__
-|                    ^  NO<sub>x</sub>  ^  SO<sub>x</sub>  ^  CO    ^  NMVOC  ^  TSP  ^  PM<sub>10</sub>  ^  PM<sub>2.5</sub>  ^  PAH     ^  PCDD/  ^ +|                    ^  NO<sub>x</sub>  ^  SO<sub>x</sub>  ^  CO    ^  NMVOC  ^  TSP  ^  PM<sub>10</sub>  ^  PM<sub>2.5</sub>  ^  PAH      ^  PCDD/  ^ 
-|                    ^  [kg/TJ]                                                                                          ||||||^  Fuel    ^  [kg/TJ] +|                    ^  [kg/TJ]                                                                                          ||||||^  [mg/TJ]  ^  [kg/TJ] 
-^ Hard Coal          |             89.8 |            331.7 |  2,162 |    30.3 |  18.5 |              17.6 |               15.7 |   19,215 |      16.3 | +^ Hard Coal          |             89.8 |            331.7 |  2,162 |    30.3 |  18.5 |              17.6 |               15.7 |    19,215 |      16.3 | 
-^ Residual Wood      |             92.7 |              8.2 |  931.5 |    66.8 |  46.5 |              44.6 |               40.0 |  144,957 |     355.3 | +^ Residual Wood      |             92.7 |              8.2 |  931.5 |    66.8 |  46.5 |              44.6 |               40.0 |   144,957 |     355.3 | 
-^ Light Heating Oil  |             43.7 |              3.3 |   11.9 |     2.3 |   1.0 |               1.0 |                1.0 |    20.15 |       2.7 | +^ Light Heating Oil  |             43.7 |              3.3 |   11.9 |     2.3 |   1.0 |               1.0 |                1.0 |     20.15 |       2.7 | 
-^ Natural Gas        |             22.0 |              0.1 |   12.0 |     0.4 |  0.03 |              0.03 |               0.03 |     3.08 |       1.6 |+^ Natural Gas        |             22.0 |              0.1 |   12.0 |     0.4 |  0.03 |              0.03 |               0.03 |      3.08 |       1.6 |
  
 TSP and PM emission factors are to a large extend based on measurements without condensed compounds, according to CEN-TS 15883, annex I. TSP and PM emission factors are to a large extend based on measurements without condensed compounds, according to CEN-TS 15883, annex I.
Line 63: Line 63:
  
 ==== Persistent Organic Pollutants ==== ==== Persistent Organic Pollutants ====
-{{:sector:energy:fuel_combustion:small_combustion:1a4ai_em_pcddf.png?400|Annual PCDD/F emissions in NFR 1.A.4.a.i}} +{{:sector:energy:fuel_combustion:small_combustion:1a4ai_em_pcddf.png?800|Annual PCDD/F emissions in NFR 1.A.4.a.i}} 
-{{:sector:energy:fuel_combustion:small_combustion:1a4ai_em_pah.png?400|Annual PAH emissions in NFR 1.A.4.a.i}}+{{:sector:energy:fuel_combustion:small_combustion:1a4ai_em_pah.png?800|Annual PAH emissions in NFR 1.A.4.a.i}}
  
 The main driver of the POPs emission trend are coal and fuel-wood. PCDD/F emissions decrease from 1990 to 2003 due to decreasing lignite consumption. The use of firewood and therefore PCDD/F emissions from wood combustion show a constant development. The main driver of the POPs emission trend are coal and fuel-wood. PCDD/F emissions decrease from 1990 to 2003 due to decreasing lignite consumption. The use of firewood and therefore PCDD/F emissions from wood combustion show a constant development.
Line 71: Line 71:
  
 Recalculations were necessary for 2020 due to the implementation of the now finalised National Energy Balance.  Recalculations were necessary for 2020 due to the implementation of the now finalised National Energy Balance. 
- 
-Furthermore, compared to submission 2021, PAH emissions have been recalculated for all small combustion sources due to a revision of emission factors applied.