sector:energy:fuel_combustion:small_combustion:stationary_small_combustion:commercial_institutional [2023/04/13 12:57] – [Activity data] niebuhrsector:energy:fuel_combustion:small_combustion:stationary_small_combustion:commercial_institutional [2023/04/19 11:29] (current) – [Recalculations] niebuhr
Line 23: Line 23:
 ==== Emission factors ==== ==== Emission factors ====
  
-For further information on the emission factors applied please refer to the [[sector:energy:fuel_combustion:small_combustion:stationary_small_combustion |superordinte chapter]] on small stationary combustion.+For further information on the emission factors applied please refer to the [[sector:energy:fuel_combustion:small_combustion:stationary_small_combustion |superordinate chapter]] on small stationary combustion.
  
 __Table 1: Emission factors for commercial and institutional combustion installations__ __Table 1: Emission factors for commercial and institutional combustion installations__
-|                    ^  NO<sub>x</sub>  ^  SO<sub>x</sub>  ^  CO    ^  NMVOC  ^  TSP  ^  PM<sub>10</sub>  ^  PM<sub>2.5</sub>  ^  PAH     ^  PCDD/  ^ +|                    ^  NO<sub>x</sub>  ^  SO<sub>x</sub>  ^  CO    ^  NMVOC  ^  TSP  ^  PM<sub>10</sub>  ^  PM<sub>2.5</sub>  ^  PAH      ^  PCDD/  ^ 
-|                    ^  [kg/TJ]                                                                                          ||||||^  Fuel    ^  [kg/TJ] +|                    ^  [kg/TJ]                                                                                          ||||||^  [mg/TJ]  ^  [kg/TJ] 
-^ Hard Coal          |             89.8 |            331.7 |  2,162 |    30.3 |  18.5 |              17.6 |               15.7 |   19,215 |      16.3 | +^ Hard Coal          |             89.8 |            331.7 |  2,162 |    30.3 |  18.5 |              17.6 |               15.7 |    19,215 |      16.3 | 
-^ Residual Wood      |             92.7 |              8.2 |  931.5 |    66.8 |  46.5 |              44.6 |               40.0 |  144,957 |     355.3 | +^ Residual Wood      |             92.7 |              8.2 |  931.5 |    66.8 |  46.5 |              44.6 |               40.0 |   144,957 |     355.3 | 
-^ Light Heating Oil  |             43.7 |              3.3 |   11.9 |     2.3 |   1.0 |               1.0 |                1.0 |    20.15 |       2.7 | +^ Light Heating Oil  |             43.7 |              3.3 |   11.9 |     2.3 |   1.0 |               1.0 |                1.0 |     20.15 |       2.7 | 
-^ Natural Gas        |             22.0 |              0.1 |   12.0 |     0.4 |  0.03 |              0.03 |               0.03 |     3.08 |       1.6 |+^ Natural Gas        |             22.0 |              0.1 |   12.0 |     0.4 |  0.03 |              0.03 |               0.03 |      3.08 |       1.6 |
  
 TSP and PM emission factors are to a large extend based on measurements without condensed compounds, according to CEN-TS 15883, annex I. TSP and PM emission factors are to a large extend based on measurements without condensed compounds, according to CEN-TS 15883, annex I.
Line 70: Line 70:
 ===== Recalculations ===== ===== Recalculations =====
  
-Recalculations were necessary for 2020 due to the implementation of the now finalised National Energy Balance.  +Recalculations for 2020 were necessary due to the implementation of the now finalised National Energy Balance. For the years 2005 to 2020 changes in the activity data for solid biomass and paraffin oil (only 2019) made recalculations necessary.
- +
-Furthermore, compared to submission 2021, PAH emissions have been recalculated for all small combustion sources due to a revision of emission factors applied.+