meta data for this page
  •  

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
sector:ippu:mineral_industry:construction_demolition:start [2023/03/14 12:08] – [Table] kotzullasector:ippu:mineral_industry:construction_demolition:start [2023/04/12 17:25] (current) – [Recalculations] kludt
Line 25: Line 25:
 The emission factors used are results of Adaptation of UNECE-Defaults (EEA, 2016) [(EEA2016>EEA, 2016: EEA Report No 21/2016 EMEP EEA air pollutant emission inventory guidebook 2016, Copenhagen, 2016; https://www.eea.europa.eu/ds_resolveuid/EJ6RT9P2Y3)], see chapter NFR 2.A.5.b for different kind of buildings. The emission factors used are results of Adaptation of UNECE-Defaults (EEA, 2016) [(EEA2016>EEA, 2016: EEA Report No 21/2016 EMEP EEA air pollutant emission inventory guidebook 2016, Copenhagen, 2016; https://www.eea.europa.eu/ds_resolveuid/EJ6RT9P2Y3)], see chapter NFR 2.A.5.b for different kind of buildings.
  
-__Table 1: Overview of apllied emission factors__ +__Table 1: Overview of apllied emission factors, in [kg / m<sup>2</sup> * y]__ 
-^ Kind of building                 |^ Pollutant             |^ EF value     |^ Unit         |^ EF trend         ||| +^ Kind of building               Pollutant          EF value   EF trend  ^ 
-| single and two family houses     ||  TSP                  ||  0.0638      ||  kg/m²*y     ||  constant        ||+| single and two family houses  |  TSP               |  0.0638    |  constant  | 
-single and two family houses     ||  PM<sub>10</sub>      ||  0.0191      ||  kg/m²*y     ||  constant        ||+:::                           |  PM<sub>10</sub>   |  0.0191    |  constant  | 
-single and two family houses     ||  PM<sub>2.5</sub>     ||  0.0019      ||  kg/m²*y     ||  constant        ||+:::                           |  PM<sub>2.5</sub>  |  0.0019    |  constant  | 
-| apartment buildings              ||  TSP                  ||  0.329       ||  kg/m²*y     ||  constant        ||+| apartment buildings           |  TSP               |  0.329      constant  
-apartment buildings              ||  PM<sub>10</sub>      ||  0.099       ||  kg/m²*y     ||  constant        ||+:::                           |  PM<sub>10</sub>   |  0.099      constant  
-apartment buildings              ||  PM<sub>2.5</sub>     ||  0.0099      ||  kg/m²*y     ||  constant        ||+:::                           |  PM<sub>2.5</sub>  |  0.0099    |  constant  | 
-| non-residential                  ||  TSP                  ||  0.631       ||  kg/m²*y     ||  constant        ||+| non-residential               |  TSP               |  0.631      constant  
-non-residential                  ||  PM<sub>10</sub>      ||  0.189       ||  kg/m²*y     ||  constant        ||+:::                           |  PM<sub>10</sub>   |  0.189      constant  
-non-residential                  ||  PM<sub>2.5</sub>     ||  0.0189      ||  kg/m²*y     ||  constant        ||+:::                           |  PM<sub>2.5</sub>  |  0.0189    |  constant  | 
-| roads                            ||  TSP                  ||  1,674       ||  kg/m²*y     ||  constant        ||+| roads                         |  TSP               |  1,674      constant  
-roads                            ||  PM<sub>10</sub>      ||  502         ||  kg/m²*y     ||  constant        ||+:::                           |  PM<sub>10</sub>   |  502       |  constant  | 
-roads                            ||  PM<sub>2.5</sub>     ||  50.2        ||  kg/m²*y     ||  constant        |||+:::                           |  PM<sub>2.5</sub>  |  50.2      |  constant  |
  
 Several further assumptions were necessary to use the formula of the Guidebook: Several further assumptions were necessary to use the formula of the Guidebook:
-| EM = EF*B*f*m     ||+| EM = EF * B * f * m     ||
  
 The EF is adapted with Moisture Level Correction factor and Silt Content Correction factor in all cases, both 0.20 and 2.22. The assumption about the duration of the construction activity uses the Default values (EEA, 2016)[(EEA2016)]: The EF is adapted with Moisture Level Correction factor and Silt Content Correction factor in all cases, both 0.20 and 2.22. The assumption about the duration of the construction activity uses the Default values (EEA, 2016)[(EEA2016)]:
Line 58: Line 58:
  
 ===== Recalculations ===== ===== Recalculations =====
-With **activity data** and **emission factors** remaining unrevised, no recalculations have been carried out compared to last year's submission. 
  
 <WRAP center round info 60%> <WRAP center round info 60%>
-For **pollutant-specific information on recalculated emission estimates for Base Year and 2019**, please see the pollutant specific recalculation tables following [[general:recalculations:start|chapter 8.1 - Recalculations]].+With **activity data and emission factors remaining unrevised**, no recalculations were carried out compared to Submission 2022.
 </WRAP> </WRAP>
 +
  
 =====Planned improvements ===== =====Planned improvements =====