meta data for this page
  •  

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Last revisionBoth sides next revision
appendices:appendix2.1_reporting_of_pm_emissions [2021/04/14 22:03] kotzullaappendices:appendix2.1_reporting_of_pm_emissions [2021/06/18 12:29] – [Table] hausmann
Line 1: Line 1:
 ======Appendix 2.1 - Reporting of PM emissions ====== ======Appendix 2.1 - Reporting of PM emissions ======
  
-__Table A2.1: Inclusion/exclusion of the condensable component from PM,,10,, and PM,,2.5,, emission factors__  +__Table A2.1: Inclusion/exclusion of the condensable component from PM<sub>10</sub> and PM<sub>2.5</sub> emission factors__  
-(NOTE: NFR categories with no reported activity or PM emissions (notation keys 'NO' or 'NA' in the NFR tables) are excluded here!) + 
 +<WRAP center round info 60%> 
 +NFR categories with no reported activity or PM emissions (notation keys 'NO' or 'NA' in the NFR tables) are excluded here.)  
 +</WRAP> 
 ^  **NFR code**        **Source / sector name**                                                                                **condensable component**                  |^  **EF reference and/or comments**                   ^ ^  **NFR code**        **Source / sector name**                                                                                **condensable component**                  |^  **EF reference and/or comments**                   ^
 |                                                                                                                              **included**                **excluded**  |                                                     | |                                                                                                                              **included**                **excluded**  |                                                     |
-^ **NFR 1 - Energy**                                                                                                                                                                                                             ^^^^^+^ **NFR 1 - Energy**                                                                                                                                                                                                             |||||
 |  1.A.1.a            | Public electricity and heat production                                                                  |                              x                                                                 | |  1.A.1.a            | Public electricity and heat production                                                                  |                              x                                                                 |
 |  1.A.1.b            | Petroleum refining                                                                                      |                              x                                                                 | |  1.A.1.b            | Petroleum refining                                                                                      |                              x                                                                 |
Line 32: Line 36:
 |  1.A.4.a i          | Commercial/Institutional: Stationary                                                                    |                              x                                                                 | |  1.A.4.a i          | Commercial/Institutional: Stationary                                                                    |                              x                                                                 |
 |  1.A.4.a ii         | Commercial/Institutional: Mobile                                                                        |  **x<sup>1</sup>**          |                | country-specific EF likely to include condensables  | |  1.A.4.a ii         | Commercial/Institutional: Mobile                                                                        |  **x<sup>1</sup>**          |                | country-specific EF likely to include condensables  |
-|  1.A.4.b i          | Residential: Stationary                                                                                                                         |                                                     |+|  1.A.4.b i          | Residential: Stationary                                                                                 |                             |  x             |                                                     |
 |  1.A.4.b ii         | Residential: Household and gardening (mobile)                                                            **?**                                      || country-specific EF without clear indication        | |  1.A.4.b ii         | Residential: Household and gardening (mobile)                                                            **?**                                      || country-specific EF without clear indication        |
 |  1.A.4.c i          | Agriculture/Forestry/Fishing: Stationary                                                                |                              x                                                                 | |  1.A.4.c i          | Agriculture/Forestry/Fishing: Stationary                                                                |                              x                                                                 |
Line 39: Line 43:
 |  1.A.5.a            | Other stationary (including military)                                                                                                x                                                                 | |  1.A.5.a            | Other stationary (including military)                                                                                                x                                                                 |
 |  1.A.5.b            | Other, Mobile (including military, land based and recreational boats)                                    **x<sup>1</sup>**          |                | country-specific EF likely to include condensables  | |  1.A.5.b            | Other, Mobile (including military, land based and recreational boats)                                    **x<sup>1</sup>**          |                | country-specific EF likely to include condensables  |
-|  1.B.1.a                                                |  Fugitive emission from solid fuels: Coal mining and handling         | x                                                                                                                                                                       +|  1.B.1.a            |  Fugitive emission from solid fuels: Coal mining and handling                                                                       | x                                                                  
-|  1.B.1.b                                                |  Fugitive emission from solid fuels: Solid fuel transformation        | x                                                                                                                                                                       +|  1.B.1.b            |  Fugitive emission from solid fuels: Solid fuel transformation                                                                      | x                                                                  
-|  1.B.2.c                                                |  Venting and flaring (oil, gas, combined oil and gas)               |      | **?**  ||  EMEP GB 2016 EF without any indication                             |+|  1.B.2.c            |  Venting and flaring (oil, gas, combined oil and gas)                                                   | **?**                                       ||  EMEP GB 2016 EF without any indication             |
  
 ^ **NFR 2 - IPPU**                                                                                                                                                                                                                                                                        ^^^^|                                                                     | ^ **NFR 2 - IPPU**                                                                                                                                                                                                                                                                        ^^^^|                                                                     |
Line 101: Line 105:
 |  11.B                                                    Forest fires                                                                                                       ||      | **?**                                                                                                EMEP GB 2016 EF without any indication                             | |  11.B                                                    Forest fires                                                                                                       ||      | **?**                                                                                                EMEP GB 2016 EF without any indication                             |
  
-^^1^^ Due to the conditions during test-bench measurements applied for type/mitigation/Euro norm approval, the Country-specific emission factors for passenger cars, light and heavy-duty vehicles (both on- and offroad), mopeds and motorcyles also include a condensable fraction. The same is assumed to be the case for engines approved for and installed in railways and boats/vessels/ships.+<sup>1</sup> Due to the conditions during test-bench measurements applied for type/mitigation/Euro norm approval, the Country-specific emission factors for passenger cars, light and heavy-duty vehicles (both on- and offroad), mopeds and motorcyles also include a condensable fraction. The same is assumed to be the case for engines approved for and installed in railways and boats/vessels/ships.