meta data for this page
This is an old revision of the document!
5.D.1 - Domestic & Commercial Wastewater Handling
Short description
NFR-Code | Name of Category | Method | AD | EF | Key Category 1 |
---|---|---|---|---|---|
5.D.1 | Domestic & Commercial Wastewater Handling | T1 | NS | D | no key categor |
Method
Emissions reported under this category are calculated using the Tier 1 approach of the EMEP/EEA Guidebook 2016, where the emission factor (EF) is 15 mg/m³ wastewater (Part B, 5.D, chap. 3.2.2, Table 3-1, p. 7). This EF is multiplied with the total amount of wastewater (AD) treated in domestic and commercial wwt-plants, following the equation:
Emissions (NMVOC) = AD x EF (ibid., chap. 3.2.1)
Activity data
Total volumes of treated municipal wastewater are derived by the German statistical agency (Statistisches Bundesamt, Fachserie 19, Reihe 2.1.2). The data source is published on a three-year basis with new data only for the respective year of the update. The availability of the data starts in 1991 with an exception for the following update, which was for 1995. Missing data are inter- or extrapolated
Emisson factors
See method
Uncertainties
The AD from Statistisches Bundesamt have an uncertainty of ±3% (normal distribution) whereas the uncertainty for the EF, due to its range (5/50 mg/m³), is -70 / +210 % and the distribution lognormal.
Recalculations
Recalculations were not necessary
Planned improvements
Currently no improvements are planned.